Tags
Language
Tags
November 2024
Su Mo Tu We Th Fr Sa
27 28 29 30 31 1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30

Practical Power Systems Protection By Using Etap Software

Posted By: ELK1nG
Practical Power Systems Protection By Using Etap Software

Practical Power Systems Protection By Using Etap Software
Published 11/2023
MP4 | Video: h264, 1920x1080 | Audio: AAC, 44.1 KHz
Language: English | Size: 2.92 GB | Duration: 3h 16m

The easiest way to become a professional power systems protection electrical engineer

What you'll learn

How draw single line diagram for any substation

How to enter technical data for electrical equipments in your substation single line diagram

Cable Protection

Transformer Protection

Motor protection

Motor Setting

static and lumped load protection

Minature Cirucit Breaker Curve

Molded Case Circuit Breaker Curve

Air Circuit Breaker Curve

Fuse Curve

Over Load Device Curve

Relay Curve (Definte and Inverse Time curve)

Coordination Between MCB and MCCB

Coordination Between MCCB and ACB

Coordination Between MCCB and Over Load device

Coordination Between Relays

Etap Star Pd Toolbar

Etap Star View Toolbar

Etap Tcc Toolbar

Requirements

No Experience needed

Description

my name is Abdelrahman , i am an electrical power system protection engineer , i will introduce to you course in electrical power system protection with title practical power systems protection by using etapin this course i will show you how you can using etap software to perform successfully protection and coordination study in systems with voltage less than 1 kv and systems with voltage above 1 kv , lets start to introduce the contents of courseFirst I will talk about how to draw single line diagram through etap typical as the single line diagram that came from consultantSecond , I will talk about how to enter technical data to all ac elements in your single line diagramThird I will talk about star protection and coordination module in etap and how you can use this module to perform protection and coordination studyIn this part I will talk about EDIT STUDY CASE TOOLBAR, STAR VIEW TOOLBAR, STAR PD TOOLBAR and TCC TOOLBARE in detailsAfter that I will talk about Cable Protection,In this part I will talk about Cable Protection ,How To Adjust Any Protection Function Had Included In Minature Circuit Breaker and How To Adjust Any Protection Function Had Included In Molded Case BreakerThen I will talk about Motor Protection & SettingIn this part I will talk about Motor Protection & Setting , MOTOR SETTING and MOTOR PROTECTIONAfter that I will talk about coordination study in systems under 1000 voltIn this part I will talk about COORDINATION STUDY BETWEEN MCB & ACB , COORDINATION STUDY BETWEEN MCCB & ACB and COORDINATION STUDY BETWEEN Over load ,MCCB & ACBNOTE :THE EXPLAINING IN THIS PART WILL BE ON LOW VOLTAGE SWITCHGEAR FROM ABB COMPANYAfter we finished explaining the protection and coordination for low voltage systems now I will talk about protection and coordination for systems above 1000 voltIn this part I will talk about motor protectionIn motor protection part I will talk about how to adjust the protection functions that included in motor protection relay as as exampleI will explain how you can adjust and what is the value for thermal overload protection function ,excessive start up protection function , short circuit protection function and ground fault protection function by using protection relay from ABB and built in etapAfter that I will talk about transformer protectionIn this part I will explain how you can adjust and what is the value for over current protection function , short circuit protection function and earth fault protection functionAfter that I will explain how you can do successfully coordination study between three protection relay motor relay , feeder relay on secondary side of transformer and and relay on primary side of transformer for phase protectionFinally I will explain how you can do successfully coordination study between three protection relay motor relay , feeder relay on secondary side of transformer and and relay on primary side of transformer for ground protectionNOTE :THE EXPLAINING IN THIS PART WILL BE ON SWITCHGEAR FROM ABB COMPANY WITH RATED VOLTAGE ABOVE 1000 VOLT

Overview

Section 1: Introduction

Lecture 1 Introduction

Section 2: Converting Any Electrical Drawing To Single Line Diagram Through Etap

Lecture 2 HOW TO DRAWING SLD

Section 3: Insertion Any Technical Data For Any Electrical Equipment In Your Single Line

Lecture 3 Course Projects download link

Lecture 4 HOW TO ENTER TECHNICAL DATA

Section 4: Etap Star Protection & Coordination Module

Lecture 5 EDIT STUDY CASE TOOLBAR

Lecture 6 STAR VIEW TOOLBAR

Lecture 7 STAR PD TOOLBAR

Lecture 8 TCC TOOLBARE

Section 5: Cable Protection

Lecture 9 Cable Protection

Section 6: How To Adjust Any Protection Function Had Included In Minature Circuit Breaker

Lecture 10 MCB SETTING

Section 7: How To Adjust Any Protection Function Had Included In Molded Case Breaker

Lecture 11 MCCB SETTING

Section 8: Motor Protection & Setting

Lecture 12 MOTOR SETTING

Lecture 13 MOTOR PROTECTION

Section 9: Coordination Study

Lecture 14 COORDINATION STUDY BETWEEN MCB & ACB

Lecture 15 COORDINATION STUDY BETWEEN MCCB & ACB

Lecture 16 COORDINATION STUDY BETWEEN OVER LOAD ,MCCB & ACB

Section 10: MEDIEUM AND HIGH VOLTAGE PROTECTION

Lecture 17 MOTOR PROTECTION ,TRANSFORMER PROTECTION & FEEDER PROTECTION

Lecture 18 GROUND -MOTOR PROTECTION ,TRANSFORMER PROTECTION & FEEDER PROTECTION

This course is for qualified electricians, professional engineers, EITs, drafters, equipment reps, suppliers, and distributors. This course is also useful for facility engineers and managers, utility personnel, and individuals who are interested in Utility Distribution System.