    The Design and Layout of Fire Sprinkler Systems, Second Edition

    Posted By: maxxum
    The Design and Layout of Fire Sprinkler Systems, Second Edition

    Mark Bromann, «The Design and Layout of Fire Sprinkler Systems, Second Edition»
    CRC | ISBN 1587160242 | 2 edition (April 5, 2001) | PDF | 5.4 Mb | 304 Pages



    DOWNLOAD FROM:


    MiRRORS @ ftp2share.com



    Thanks to darshiva !!



    Now in an updated second edition, this is a basic introduction to fire sprinkler system design and layout. The presentation is thorough and systematic, covering details of design, materials and code requirements. It serves both experienced fire safety personnel and beginners who require detailed information on this important and specialized work in fire safety engineering. Special features include study questions and answers, more than 150 sample diagrams, checklists, sample forms and spec sheets, photographs, and a glossary of words related to fire sprinkler systems and other areas of fire protection engineering.


    Table Of Contents:

    Introduction xi
    Fire Sprinklers: Their History and Background
    1 (4)
    Citations
    3 (1)
    Endnotes
    3 (2)
    Overview of a Basic Sprinkler System Design (Getting Started)
    5 (4)
    Plans and Specifications
    5 (1)
    Starting the Work on Your Plan
    6 (2)
    Citations
    8 (1)
    Endnotes
    8 (1)
    Basic Design Overview (Part 2)
    9 (4)
    Citations
    11 (1)
    Endnotes
    11 (2)
    Further Specifics of Design Basics
    13 (8)
    Dimensioning Pipe Lengths
    14 (1)
    Considerations for Office Areas
    15 (1)
    Take-Outs
    16 (1)
    Noted Dimensions
    16 (1)
    The System Header
    17 (2)
    At the End of the Job
    19 (1)
    Citations
    19 (1)
    Endnotes
    19 (2)
    Additional Engineering Responsibilities
    21 (6)
    Locate Sprinklers in an Open Space
    21 (1)
    Some Other Red Flags
    22 (1)
    The Consulting Engineer's Onus
    22 (1)
    Hazard Evaluation
    22 (1)
    On-the-Job Responsibilities
    23 (1)
    Critical Design Considerations
    23 (1)
    Communicate!
    24 (1)
    Always Be on the Alert
    25 (1)
    Citations
    25 (1)
    Endnotes
    25 (2)
    Finishing the Plan
    27 (4)
    Endnotes
    29 (2)
    Stocklisting
    31 (4)
    Endnotes
    32 (3)
    Areas Subject to Freezing
    35 (4)
    Auxiliary Dry Systems
    35 (1)
    Anti-Freeze Systems
    36 (1)
    Factors to Consider
    36 (1)
    Sprinkler System Conversions
    37 (1)
    Engineering Design Options
    38 (1)
    Citations
    38 (1)
    Endnotes
    38 (1)
    Pipe Hanging
    39 (4)
    Endnote
    42 (1)
    System Code Requirements
    43 (8)
    Customizing Your Work to the Job at Hand
    44 (1)
    Code Specifics
    44 (1)
    Making Use of NFPA Pamphlet #13
    45 (1)
    Study Questions
    46 (3)
    Citation
    49 (1)
    Endnotes
    49 (2)
    Basics of Hydraulic Calculation
    51 (8)
    The Project Example
    51 (1)
    Primary Calculation Considerations
    52 (3)
    Cross-Main Calculation Procedures
    55 (1)
    Completing the Hydraulic Calculation
    55 (1)
    Proving System Adequacy
    56 (1)
    Some Finer Points
    56 (1)
    System Variations
    57 (1)
    Citations
    58 (1)
    Endnotes
    58 (1)
    Preparation for the Nicet Examination
    59 (8)
    Study Questions
    61 (3)
    Citations
    64 (1)
    Endnotes
    65 (2)
    Piping Methods and Details
    67 (6)
    Endnotes
    72 (1)
    Options for Hydraulic Design
    73 (6)
    The Grid Calculation
    74 (2)
    The Loop Calculation
    76 (1)
    To Bear in Mind
    77 (1)
    Citations
    77 (1)
    Endnotes
    77 (2)
    High-Piled Storage
    79 (10)
    Commodity Classification
    79 (1)
    Commodity Piling Height
    80 (1)
    Code Application
    80 (1)
    Another Application Example
    81 (1)
    Sprinkler Options
    82 (1)
    Study Questions
    83 (4)
    Citations
    87 (1)
    Endnotes
    87 (2)
    Techniques for Retrofit Work
    89 (6)
    Measure and Quantify the Existing Building in Three Dimensions
    90 (1)
    Prepare the Design and Layout by Survey
    91 (1)
    Make a Comprehensive Effort
    92 (1)
    Recent Examples of Retrofit Design Work
    92 (1)
    Citations
    93 (1)
    Endnotes
    93 (2)
    The Role of Fire Pumps and Their Usage
    95 (6)
    The Horizontal Electric Fire Pump
    96 (1)
    Vertical Turbine Pumps
    96 (1)
    In-Line and End-Section Pumps
    96 (1)
    Diesel-Drive Pumps
    97 (1)
    Pump Selection
    97 (1)
    Energy for Start-Up and Operation
    98 (1)
    The Codes
    98 (1)
    Code Interpretations
    99 (1)
    Field Engineering Concerns
    99 (1)
    Size and Safety
    100 (1)
    Citations
    100 (1)
    Basics of Fire Pump Layout
    101 (8)
    Proper Proximity of the Pump
    101 (1)
    What the Code Dictates
    102 (1)
    Fire Alarm Control Panels
    103 (1)
    Fire Pump Performance Curves
    104 (1)
    Sizing the Fire Pump
    104 (1)
    Detailing the Pump Plan
    105 (1)
    Installation Considerations
    105 (1)
    Fire Pump Testing Apparatus
    106 (1)
    Endnotes
    107 (2)
    Residential Fire Sprinkler Design
    109 (10)
    Project Design Considerations
    110 (1)
    NFPA Pamphlet #13-R Requirements
    111 (1)
    Laying Out the System Piping
    112 (1)
    Residential Sprinkler Plan Preparation
    112 (1)
    The Intent and Significance of Pamphlet #13-R
    113 (1)
    Study Questions
    114 (4)
    Citations
    118 (1)
    Additional Referenced Material
    118 (1)
    Endnotes
    118 (1)
    Project Estimating
    119 (4)
    Endnotes
    122 (1)
    Economies of the Design Function
    123 (6)
    Citations
    128 (1)
    Endnotes
    128 (1)
    Appendix A: Fire Sprinkler Application Review 129 (4)
    Appendix B: In-House Engineer Training 133 (3)
    Appendix C: Protecting Computer Rooms 136 (3)
    Appendix D: Figures and Photos 139 (139)
    Appendix E: Friction Loss Tables for Thinwall Cross-mains Black Schedule 10 Steel Pipe C = 120 Friction Loss–-PSI per lineal foot of pipe 278 (3)
    Answer Key 281 (2)
    Glossary 283 (6)
    Index