Introduction To Solar Pv And Diesel Generator Hybrid System
Published 6/2023
MP4 | Video: h264, 1280x720 | Audio: AAC, 44.1 KHz
Language: English | Size: 1.20 GB | Duration: 2h 20m
Published 6/2023
MP4 | Video: h264, 1280x720 | Audio: AAC, 44.1 KHz
Language: English | Size: 1.20 GB | Duration: 2h 20m
Your Guide for Sustainable Learning
What you'll learn
Introduction to PV DG Hybrid System
Why PV DG Hybrid System is Used
Components of PV DG Hybrid System
Working of PV DG Hybrid System
Why PV DG Synchronization Controller Required
Benefits of PV DG hybrid system
Alternative names for PV Genset Controller
Why PV DG Synchronization Controller Required
Minimum Loading
Common Symptoms due to minimum loading include
Reverse Power Protection
Reactive Power management
Spinning Reverse & Grid Export
When and where is a PV diesel hybrid system make sense
Fuel consumption chart provided by DG Manufacturers is not a practical reference
Calculation of Fuel Saving in PV DG Hybrid System
In which scenarios PV Genset Controller will not be productive.
Impacts of Genset Under loading or Wet Stacking
Why is a PV Genset controller not suggested for personal or residential applications?
Grid-connected solar inverters with generators under Reactive Power control
For the installation of a PV Genset Controller, what generator size is recommended
What is a solar inverter zero export or zero feed in device. Does the PV Genset controller have this capability
A PV genset controller's advantages
A PV genset controller's advantages according to Grid
A PV genset controller's advantages according to Generator
Calculation of Maximum Solar Injection
Design of PV DG Hybrid System Case Study
Sizing the Solar Plant
DC Combiner Box
DC/AC Cable Selection
ACDB Selection
Diesel Generator Selection
PV DG Synchronization Controller
Economics of PV DG Hybrid Project
Fuel Saving with PV DG Hybrid Project
Requirements
Basic Prior knowledge is required for Photovoltaic Solar System. Diesel Generator working concepts has covered from basics to intermediate level.
Description
In this course you will learn following points in detail:Introduction to PV DG Hybrid SystemWhy PV DG Hybrid System is UsedComponents of PV DG Hybrid SystemWorking of PV DG Hybrid SystemWhy PV DG Synchronization Controller RequiredBenefits of PV DG hybrid systemAlternative names for PV Genset ControllerWhy PV DG Synchronization Controller RequiredMinimum LoadingCommon Symptoms due to minimum loading includeReverse Power ProtectionReactive Power managementSpinning Reverse & Grid ExportWhen and where is a PV diesel hybrid system make senseFuel consumption chart provided by DG Manufacturers is not a practical referenceCalculation of Fuel Saving in PV DG Hybrid SystemIn which scenarios PV Genset Controller will not be productive.Impacts of Genset Under loading or Wet StackingWhy is a PV Genset controller not suggested for personal or residential applications?Grid-connected solar inverters with generators under Reactive Power controlFor the installation of a PV Genset Controller, what generator size is recommendedWhat is a solar inverter zero export or zero feed in device. Does the PV Genset controller have this capabilityA PV genset controller's advantagesA PV genset controller's advantages according to GridA PV genset controller's advantages according to GeneratorCalculation of Maximum Solar InjectionDesign of PV DG Hybrid System Case StudySizing the Solar PlantDC Combiner BoxDC/AC Cable SelectionACDB SelectionDiesel Generator SelectionPV DG Synchronization ControllerEconomics of PV DG Hybrid ProjectFuel Saving with PV DG Hybrid Project
Overview
Section 1: Introduction to Solar Photovoltaics and Diesel Generator Hybrid System
Lecture 1 Introduction about the Course
Lecture 2 Introduction to Photovoltaics Diesel Generator Hybrid System
Lecture 3 Why PV DG Hybrid System is Used
Lecture 4 Components of PV DG Hybrid System
Lecture 5 Benefits of PV DG hybrid system
Section 2: Working of PV DG Hybrid System
Lecture 6 Basics of Working of PV DG Hybrid System
Lecture 7 Working of PV DG Hybrid System - DG Hunting
Section 3: PV DG Synchronization Controller and its functionalities
Lecture 8 Alternative names for PV Genset Controller
Lecture 9 Why PV DG Synchronization Controller Required
Lecture 10 Minimum Loading
Lecture 11 Common Symptoms due to minimum loading include:
Lecture 12 Reverse Power Protection
Lecture 13 Reactive Power management
Lecture 14 Spinning Reverse
Lecture 15 Grid Export
Lecture 16 Solar inverter zero export or zero feed in device.
Lecture 17 PV DG controller's advantages according to Grid, Diesel Generator & in General
Section 4: Fuel Saving due to Minimum Loading of DG Genset due to PV DG Hybrid System
Lecture 18 Fuel consumption chart provided by DG Manufacturers is not a practical reference
Lecture 19 Calculation of Fuel Saving in PV DG Hybrid System
Section 5: When to use or avoid PV DG Hybrid System
Lecture 20 When and where is a PV diesel hybrid system make sense?
Lecture 21 In which scenarios PV Genset Controller will not be productive.
Lecture 22 Impacts of DG Genset Under loading or Wet Stacking
Lecture 23 Why is a PV Genset controller not suggested for personal or residential use
Section 6: Calculation of Diesel Generator size and Identification of Factors responsible
Lecture 24 Grid-connected solar inverters with generators under Reactive Power control
Lecture 25 Impacts may occur when the power factor drops on the generator
Lecture 26 What generator size is recommended?
Lecture 27 When PV-DG Hybrid System is recommended?
Lecture 28 When PV-DG Hybrid System is recommended? Per Phase basis
Lecture 29 Calculation of Maximum Solar Injection
Section 7: Design Calculations of of PV DG Hybrid System - Case Study
Lecture 30 Defining the Problem Statement
Lecture 31 Calculation of Maximum Solar Injection
Lecture 32 Selection and Sizing the Solar Panel
Lecture 33 Selection and Sizing the Solar Inverter
Lecture 34 Calculation of No. of Panels and String Sizing
Lecture 35 Selection of DC Combiner Box
Lecture 36 Selection of DC Cable: Solar Strings to DC Combiner Box
Lecture 37 Selection of DC Cable: DC Combiner Box to Solar Inverter
Lecture 38 Selection of AC Cable
Lecture 39 ACDB Selection
Lecture 40 Diesel Generator Selection
Lecture 41 PV DG Synchronization Controller
Lecture 42 Economics of PV DG Hybrid Project
Lecture 43 Economics of PV DG Hybrid Project - Fuel Saving & Total Savings
Beginner curious about Photovoltaics Diesel Generator Working fundamentals.,Solar PV Designer,Solar PV Consultant,Solar Business Person,Students