Tags
Language
Tags
May 2025
Su Mo Tu We Th Fr Sa
27 28 29 30 1 2 3
4 5 6 7 8 9 10
11 12 13 14 15 16 17
18 19 20 21 22 23 24
25 26 27 28 29 30 31
    Attention❗ To save your time, in order to download anything on this site, you must be registered 👉 HERE. If you do not have a registration yet, it is better to do it right away. ✌

    ( • )( • ) ( ͡⚆ ͜ʖ ͡⚆ ) (‿ˠ‿)
    SpicyMags.xyz

    Tekla Structures 2018 SP6

    Posted By: scutter
    Tekla Structures 2018 SP6

    Tekla Structures 2018 SP6 | 4.0 Gb

    The Tekla team introduced new update version of its software for structural engineering, fabrication and construction teams—Tekla Structures 2018 SP6. This update contain new features, and improvements and fixes to existing features.

    TSAC-2742 In Round joining plates (124), the antimaterial in the hole which creates a cut in the base plate is no longer shown in drawings.
    TTSD-24848 Tekla Structures now contains DWG plug-in version 1.42.
    TTSD-24392 The performance of the reference model insert has been improved when the Tekla Structures model already contains non-visible unloaded reference models. After the fix, non-visible reference models are not loaded anymore in the reference model insert.
    TTSD-24298 Drawing DWG export now outputs the Romsim font in a size that is closer to the one you see in the drawing.
    TTSD-24051 The SketchUp export did not work if the Tekla Structures model name contained special characters. This has now been fixed.
    TTSD-23950 IFC object conversion sometimes misplaced cuts. This has now been fixed.
    TTSD-23931 The scaling of the IFC export dialog box did not work with high resolution screens. This has now been fixed.
    TTSD-23475 IFC object conversion did not convert curved walls correctly in some cases. This has now been fixed.
    TTSD-23266 IFC object converter: Cut row in changes cannot be opened at some cases. This has now been fixed.
    TTSD-23264 The IFC object conversion update now keeps the user-created part cuts.
    TTSD-22387 When manually importing a new profile through the Modify Profile Catalog dialog box using the Replace option, all parts in the model could sometimes get unintentionally modified. Now all unaffected parts remain untouched after the import.
    TTSD-21384 In the IFC2x3 export, the surface treatment to all faces of the part is now properly written to the IFC model.
    TTSD-17107 IFC4 export: Tekla Structures crashed when you were using a large number of characters for the file name in the IFC4 export dialog box. This has now been fixed. If the the number of characters exceeds Microsoft Windows character limit the characters are removed from the file name.
    TTSD-14434 When creating IFC2x3 export files the application name "Tekla Structures Educational" was shown in the IFC output header even though the license was Full. This has now been fixed.
    TTSD-24940 Tekla Structures does not crash anymore when modifying a drawing even if the UDA definitions are missing from the objects.inp. The User-defined attributes dialog box is not available at all in the drawing dialog box if UDAs are missing from the environment. Previously,clicking the panel caused an application error.
    TTSD-24705 Sometimes the IFC inquire failed and did not provide all information. This has now been fixed.
    TTSD-24459 Detailed object level settings were not applied if the name from the dialog box differed from file name for the given attribute.
    TTSD-24406 When Secondary part dimension direction was set to Neighbor part in dimensioning properties, there was sometimes a crash when creating or modifying assembly drawings. This has now been fixed.
    TTSD-24041 Master Drawing Catalog can now be opened in Partner configuration again.
    TTSD-23526 Drawing views created with the Area in drawing view command were incorrectly following one part inside the view when the part moved in the model. In GA drawings, these views look like model views so now they also behave like model views in drawing update, and the area the view is showing will not change after model changes.
    TTSD-23307 Holding down Shift and dragging part marks no longer causes an assert.
    TTSD-23213 In earlier versions, if drawing dimension was selected and then it was turned off in view dimension properties, the handle points remained visible. This has now been fixed.
    TTSD-22912 Drawings with custom plug-ins using lots of graphical objects, such as lines, or rectangles, have now slightly better performance.
    TTSD-22647 Dimension post and prefix marks were incorrectly aligned. They are now again at the same y location as the dimension value text.
    TTSD-21756 Sometimes Tekla Structures showed an assert when a text was moved in a drawing using the Shift button.
    TTSD-17943 The tolerance for RD text in drawing dimensions has been adjusted so it no longer collides with the dimension text.
    TTSD-17669 Manual weld marks are no longer deleted when modifying view settings in a drawing.
    TTSD-17450 Drawing DWG export is now bit more robust with handling custom drawing of parts.
    TTSD-17250 The new printing incorrectly displayed a watermark in drawings with the Educational stamp. The text Educational was also shown in the PDF properties for a drawing. This has now been fixed.
    TTSD-15754 Sometimes the hatches did not stay inside the enclosing polygon. This has now been fixed.
    TSAC-2672 BVBS Export: The Partner and Developer configurations were added to the list of allowed configurations.
    TSAC-2600 Rebar group dimensioning: Symbols for dimensioning rebars are now placed correctly.
    TTSD-24545 Tekla Structures DataSharing facade has been upgraded to version 3.11.19.
    TTSD-23998 The Replace option for importing profiles to the profile catalog in shared models now works correctly when cross sections in the original profile and the imported profile have identical names.
    TTSD-23179 The performance of Organizer synchronization has been improved in situations where the model history contains a lot of deleted objects.
    TTSD-22960 In Tekla Model Sharing, profile import has been improved as follows:
    - Importing of .lis profiles which have double quotes followed by space in the names has been fixed.
    - Importing of .lis profiles which have duplicated cross-section points has been fixed.
    - Reliability of importing profile updates during read in has been improved.
    TTSD-24499 Previously, you could enter an invalid shape name for an item in the property pane, which would change the item into a stick. This is now prevented. Instead, Tekla Structures instructs you to select a new shape.
    TTSD-24372 Previously, the database size could become too large if you created and deleted multiple objects with UDAs. This has now been fixed.
    TTSD-20433 Selecting parts in large models is now much faster.
    TTSD-17847 When numbering (with the save-numbering-save setting selected in the Numbering set up dialog box), unnamed temporary views disappeared when canceling the numbering. This has now been fixed.
    TTSD-18955 Previously, static ID model conversion failed in some rare cases because of ID handling. This has now been fixed.
    TTSD-24560 Sometimes Tekla Structures crashed when opening or refreshing a view with polygon reinforcement meshes displayed with the Fast representation. This has now been fixed.
    TTSD-23422 The Work plane handler toolbar now works correctly when a new view is created using the part plane.
    TTSD-21857 New concrete spiral beams now show the correct pour phase number in the property pane when the pour phase has been set for other previously created concrete spiral beams.
    TSAC-2765 BVBS Export: The BVBS export now reports the diameter value as the nominal rebar diameter regardless of the XS_USE_ONLY_NOMINAL_REBAR_DIAMETER setting, according to the specification.
    TSAC-2755 Export Unitechnik (79): It is now possible to specify a user-defined concrete volume template property for export using the Concrete volume option on the SLABDATE block data tab.
    TSAC-2741 Export Unitechnik (79): It is now possible to export Unloading type using the option on the SLABDATE data block tab. Also, it is possible to set Unloading type and Transportation type on the Unitechnik tab for precast concrete parts, which overrides the export dialog box option.
    TSAC-2669 Export Unitechnik (79): New option Exclude all has been added on the Validation tab page for the setting Export others to exclude the whole mesh from the export when it fails the validation. Option No has been renamed to Remove invalid mesh wires and now it excludes only invalid mesh wires and not the whole mesh when it fails the validation as before.
    TSAC-2449 BVBS Export:
    On the Parameters tab, in the Drawing name source setting, there is a new option Assembly template available, and the Template option has been renamed to Reinforcement template.
    On the Advanced tab, click Edit or New under Private data block. This displays a list of property data types, which has been updated. The following options are now available:
    - Reinforcement report property Integer, Float or Text
    - User-defined attribute Integer, Float or Text
    - Open API object property
    - Assembly report property Integer, Float or Text
    TSAC-1525 Export Unitechnik (79): You can now validate rebar and mesh leg lengths, and mesh overhangs and spacings. Now you can also select to export non-valid rebars as non-automated or to prevent the export. The new and changes settings are located on the Validation tab.

    About Tekla Structures 2018. Tekla Structures is a building information modeling software able to model structures, such as high-rise office or residential buildings. This software is widely used in the building and construction industries for steel and concrete detailing, precast and cast in-situ. The software enables users to create and manage 3D structural models in concrete or steel, and guides them through the process from concept to fabrication.Tekla allows structural drafters and engineers to design a building structure and its components using 3D modeling, generate 2D drawings and access building information.

    Tekla Structures 2018 has been updated for greater speed and efficiency.

    This version of the BIM modeling software, Tekla Structures 2018, is designed to be faster and more precise and offer greater control. The software is also meant to be more efficient in terms of workflow. Tekla Structures 2018 now supports point clouds, making it possible to create designs that fit with existing structures. Other updates include quicker drawing “with less effort,” according to the company. The workflow from design to analysis is also meant to be smoother.

    Tekla Structures 2018 New Feature - Point Clouds


    About Tekla Software by Trimble. Tekla software solutions for advanced BIM and structural engineering are produced by Trimble. Trimble’s construction offering ranges from total stations to advanced software, giving the industry tools to transform planning, design, construction and operation of buildings. Tekla software is at the heart of the design and construction workflow, building on the free flow of information, constructible models and collaboration.

    Product: Trimble Tekla Structures
    Version: 2018 SP6 with Help and Environment
    Supported Architectures: x64
    Website Home Page : https://tekla.com/
    Language: multilanguage
    System Requirements: PC
    Supported Operating Systems: Windows 7even or newer
    Size: 4.0 Gb
    Please visit my blog

    Added by 3% of the overall size of the archive of information for the restoration

    No mirrors please


    Tekla Structures 2018 SP6