Siemens PLM NX 12.0.2 (NX 12.0 MR2) MP03 Update | 997.0 mb
Siemens PLM Software has released an update to NX NX 12.0.2 (NX 12.0 MR2), its an integrated product design, engineering and manufacturing solution that helps you deliver better products faster and more efficiently. NX 12.0.2 is an accumulation of fixes and small enhancements built.
7419803 Would like to be able to select more than one feature to tolerance
7529069 FBM/MKE: Feature teaching creates attributes of type system instead of customer
8375928 Internal error when generating toolpath
8378962 Cannot use MKE due to Channel Command errors. No Operation and Tool types available
8383257 Texts are shifted in DXF file
8384163 CAM: Feature tagging works only in the beginning of a NX-session
8384475 Product Interface objects get Out of Date status by Delay Product Interface
8386138 Electrical Routing: Part Cleanup makes loaded harness corrupt
8386538 Unable to select Region for Trimmed sheet when Feature Preview is OFF
8386617 Flat Pattern size is incorrect; Flange with tangent web length reference
8386991 AM Build support display
8387207 Bumper pendulum placed at wrong contact point
8387208 Bumper cannot be deleted
8387210 The created Bumper-feature cannot be deleted.
8387559 PMIs (Angular Dimension) are not properly transferred to SE CAM Pro
8387566 PMIs (Diameter) are not properly transferred to SE CAM Pro
8388804 bad definition of material in assembly fem
8389004 Feature recognition crashes on specific part for STEP1POCKET
8390624 license nx_point_cloud_view is checked out without been used or needed
8390941 PR- Additional Item is created in NEWSTUFF Folder
8392042 From NX Manager, using Save as New Item, NX creates two references of the item
8393774 Wrong Angle Measure in Assembly Mode
8550301 Failed to import some rst files into SC
8550644 solver cannot grasp HPC license
8550869 h-matrix and FMBEM solver try grasping license from RLM license server
8970290 Link to PMI does not get Tolerance value correctly from PMI.
9005992 CAM NX12 - FBM Incorrect Inferred Depth
9038277 Transform path on PTS parts/stock needs to retain the PTS features
9047785 Export STL angular tolerance get lost when executing translation
9073959 Drilling operation using 3D IPW doesn’t produce a tool path in NX 11.0.2
9110715 Edit sketch fails, seems to be related to a profile feature
9119486 Internal Error when Generated Fixed Contour Operation
9120750 CAM NX12 - Mirror FBM with Geometry SameAsSource Behavior
9124854 Measured Data dialog needs improvement
9134525 AG property policy causes slow down on Load
9138344 Engage and Retract set to Cut feed rate when pressing Set Machining Data
9152374 MKE returns an Channel Command Error if mrm_export_resources has used
9153762 Assign Coped Corner does not update the length attribute of the stock
9166364 Sensor angle does not change on the Inspection Path dialog.
9168490 Link to PMI fails after moving the component using Move/
9175362 Routing transform path will not copy stock across assemblies.
9177145 Sheet Metal Bend Radius can’t be set to Global Value
9183700 NXOpen.CAM InspectionMoveBuilderSensorOpName failing to return all sensor name
9186537 Dimension arrow covers value on DXF import
9189235 Output frame number on plate template
9189239 Initial Selection QuickPick annoyance when starting NX
9189269 Profile intersection trim in basic design
9197231 Need a way to check thickness direction in basic design
9199127 Straight brake parts must have the Cutting side on the inner radius
9199949 ANT Column are preforming a where Partitioned call taking time when expanding
9200301 Support for Expansion drawing from starboard to portside
9200683 PnM0 options Hole-type and Hole subtype cannot be changed at Verify Request
9202461 File Export Author HTML produces useless black and white images
9203437 JT Export not working for specific part
9206000 Drawing not saveable - Object creation is currently locked.
9206083 NXMGR: Part is not derived from a Multi-cad part file
9211204 Error when switching material removal off and on again during a simulation run
9211614 NX Auto weld symbol tail information is not always centered
9212563 3D toolpath verify takes longer in NX12.0.2 than 12.0.1 @ same settings
9212565 Saving Drawing: Object creation is currently locked
9214667 Support profile bending template
9215743 Spline path lock length slack driven by expression no longer working in NX12
9216045 File not found error to export iges in NX managed mode
9216453 NX clone Revision rule as saved using cmd
9219062 license nx_point_cloud_view is checked out without been used or needed
9220482 Unable to reference face adopt from JT after transformation matrix change
9220547 UDF thread lines do not change when editing UDF size
9222652 NX12 Solid Edge Interoperability re-specify File fails with new file location
9223389 Ribbon tabs disappear after using Simulation in Manufacturing
9224847 SaveAs to specified folder creates second reference in Newstuff-folder
9224879 Create Fabrication - selected item types does not get created via journal
9225057 Feature recognition crashes on specific part for STEP1POCKET
9225217 NX crashes during hole_making operation
9225294 Allow adding component of types not included in TCAllowedChildTypes_ preference
9226517 Editing spline path causes extension vector to reverse
9226980 Invalid Tag error trying to set work part - FMS issues
9227054 Incorrect collision detection in Machine Simulation
9227206 Drag and drop of classified items not working from Reuse library in NX
9227529 synchronization wait markers move when open the Setup in NX12.0.2
9228827 ID Symbol text lost converting to 2d
9229918 There’s no call to support minimum curve radius in MKE
9231202 Not possible to use action TCE_REFER with PDW standard parts
9234034 After replace of suppressed components NX loses connection between _IN and _OUT
9235284 Problem with post processor in NX 12.0.2
9236925 Type filter selection missing when switching windows
9239207 Problem with screen resolution setting in PostConfigurator
9239314 NX12 does not support high resolution screen settings
9239968 Threaded hole from Solid Edge causes missing threaded features error
9240116 Unnecessary warning on Find Features for new SE2019 threaded hole
9240539 Insulation fails to create on planar plate.
9245173 Error when drag & drop Inspection Path Operation to unused items in Machine View
9246014 Subprogram parameters passing doesn’t work for Okuma controller in NX12.0
9246119 After changing NX Attribute value linked expression value is not updated (Error)
9247114 Cannot add reuse library items with multiple revisions by dragging & dropping
9249905 Interpart expression is not updating attribute in NX12.0 from NX10.0 part file
9251694 Routing spline point extension vector created in the reverse direction.
9251738 No Selection Filter in Modeling is lost when switching part and editing feat.
9253230 Un-selectable geometry in shaded section view
9253770 When creating a new item with [SaveAs], it is created in the “Newstuff” folder.
9255008 Switch to Expressions creates an Internal error: memory access violation
9255208 Performance issue with the part attribute (allow multiple values option checked)
9256022 [Feature] cannot be selected
9257963 Difference between UGtoPV translation NX 9.0.3 MP15 and NX 12.0.2 MP01
9259078 Circular reference error while modify Plates
9263185 UGto2D translator fails with NX Teamcenter Integration
9265323 Ribbon tabs Disappear after using Simulation in Manufacturing
9267252 3D Dynamic Tool Path Verify is very slow when Step is pressed
9272074 Unable to import more than one revision of the same item
9273388 DXF Export failed. - Siemens PLM Component has stopped working
7529069 FBM/MKE: Feature teaching creates attributes of type system instead of customer
8375928 Internal error when generating toolpath
8378962 Cannot use MKE due to Channel Command errors. No Operation and Tool types available
8383257 Texts are shifted in DXF file
8384163 CAM: Feature tagging works only in the beginning of a NX-session
8384475 Product Interface objects get Out of Date status by Delay Product Interface
8386138 Electrical Routing: Part Cleanup makes loaded harness corrupt
8386538 Unable to select Region for Trimmed sheet when Feature Preview is OFF
8386617 Flat Pattern size is incorrect; Flange with tangent web length reference
8386991 AM Build support display
8387207 Bumper pendulum placed at wrong contact point
8387208 Bumper cannot be deleted
8387210 The created Bumper-feature cannot be deleted.
8387559 PMIs (Angular Dimension) are not properly transferred to SE CAM Pro
8387566 PMIs (Diameter) are not properly transferred to SE CAM Pro
8388804 bad definition of material in assembly fem
8389004 Feature recognition crashes on specific part for STEP1POCKET
8390624 license nx_point_cloud_view is checked out without been used or needed
8390941 PR- Additional Item is created in NEWSTUFF Folder
8392042 From NX Manager, using Save as New Item, NX creates two references of the item
8393774 Wrong Angle Measure in Assembly Mode
8550301 Failed to import some rst files into SC
8550644 solver cannot grasp HPC license
8550869 h-matrix and FMBEM solver try grasping license from RLM license server
8970290 Link to PMI does not get Tolerance value correctly from PMI.
9005992 CAM NX12 - FBM Incorrect Inferred Depth
9038277 Transform path on PTS parts/stock needs to retain the PTS features
9047785 Export STL angular tolerance get lost when executing translation
9073959 Drilling operation using 3D IPW doesn’t produce a tool path in NX 11.0.2
9110715 Edit sketch fails, seems to be related to a profile feature
9119486 Internal Error when Generated Fixed Contour Operation
9120750 CAM NX12 - Mirror FBM with Geometry SameAsSource Behavior
9124854 Measured Data dialog needs improvement
9134525 AG property policy causes slow down on Load
9138344 Engage and Retract set to Cut feed rate when pressing Set Machining Data
9152374 MKE returns an Channel Command Error if mrm_export_resources has used
9153762 Assign Coped Corner does not update the length attribute of the stock
9166364 Sensor angle does not change on the Inspection Path dialog.
9168490 Link to PMI fails after moving the component using Move/
9175362 Routing transform path will not copy stock across assemblies.
9177145 Sheet Metal Bend Radius can’t be set to Global Value
9183700 NXOpen.CAM InspectionMoveBuilderSensorOpName failing to return all sensor name
9186537 Dimension arrow covers value on DXF import
9189235 Output frame number on plate template
9189239 Initial Selection QuickPick annoyance when starting NX
9189269 Profile intersection trim in basic design
9197231 Need a way to check thickness direction in basic design
9199127 Straight brake parts must have the Cutting side on the inner radius
9199949 ANT Column are preforming a where Partitioned call taking time when expanding
9200301 Support for Expansion drawing from starboard to portside
9200683 PnM0 options Hole-type and Hole subtype cannot be changed at Verify Request
9202461 File Export Author HTML produces useless black and white images
9203437 JT Export not working for specific part
9206000 Drawing not saveable - Object creation is currently locked.
9206083 NXMGR: Part is not derived from a Multi-cad part file
9211204 Error when switching material removal off and on again during a simulation run
9211614 NX Auto weld symbol tail information is not always centered
9212563 3D toolpath verify takes longer in NX12.0.2 than 12.0.1 @ same settings
9212565 Saving Drawing: Object creation is currently locked
9214667 Support profile bending template
9215743 Spline path lock length slack driven by expression no longer working in NX12
9216045 File not found error to export iges in NX managed mode
9216453 NX clone Revision rule as saved using cmd
9219062 license nx_point_cloud_view is checked out without been used or needed
9220482 Unable to reference face adopt from JT after transformation matrix change
9220547 UDF thread lines do not change when editing UDF size
9222652 NX12 Solid Edge Interoperability re-specify File fails with new file location
9223389 Ribbon tabs disappear after using Simulation in Manufacturing
9224847 SaveAs to specified folder creates second reference in Newstuff-folder
9224879 Create Fabrication - selected item types does not get created via journal
9225057 Feature recognition crashes on specific part for STEP1POCKET
9225217 NX crashes during hole_making operation
9225294 Allow adding component of types not included in TCAllowedChildTypes_ preference
9226517 Editing spline path causes extension vector to reverse
9226980 Invalid Tag error trying to set work part - FMS issues
9227054 Incorrect collision detection in Machine Simulation
9227206 Drag and drop of classified items not working from Reuse library in NX
9227529 synchronization wait markers move when open the Setup in NX12.0.2
9228827 ID Symbol text lost converting to 2d
9229918 There’s no call to support minimum curve radius in MKE
9231202 Not possible to use action TCE_REFER with PDW standard parts
9234034 After replace of suppressed components NX loses connection between _IN and _OUT
9235284 Problem with post processor in NX 12.0.2
9236925 Type filter selection missing when switching windows
9239207 Problem with screen resolution setting in PostConfigurator
9239314 NX12 does not support high resolution screen settings
9239968 Threaded hole from Solid Edge causes missing threaded features error
9240116 Unnecessary warning on Find Features for new SE2019 threaded hole
9240539 Insulation fails to create on planar plate.
9245173 Error when drag & drop Inspection Path Operation to unused items in Machine View
9246014 Subprogram parameters passing doesn’t work for Okuma controller in NX12.0
9246119 After changing NX Attribute value linked expression value is not updated (Error)
9247114 Cannot add reuse library items with multiple revisions by dragging & dropping
9249905 Interpart expression is not updating attribute in NX12.0 from NX10.0 part file
9251694 Routing spline point extension vector created in the reverse direction.
9251738 No Selection Filter in Modeling is lost when switching part and editing feat.
9253230 Un-selectable geometry in shaded section view
9253770 When creating a new item with [SaveAs], it is created in the “Newstuff” folder.
9255008 Switch to Expressions creates an Internal error: memory access violation
9255208 Performance issue with the part attribute (allow multiple values option checked)
9256022 [Feature] cannot be selected
9257963 Difference between UGtoPV translation NX 9.0.3 MP15 and NX 12.0.2 MP01
9259078 Circular reference error while modify Plates
9263185 UGto2D translator fails with NX Teamcenter Integration
9265323 Ribbon tabs Disappear after using Simulation in Manufacturing
9267252 3D Dynamic Tool Path Verify is very slow when Step is pressed
9272074 Unable to import more than one revision of the same item
9273388 DXF Export failed. - Siemens PLM Component has stopped working
Welcome to NX 12.0.2. July 2018 - Dear Customer: NX 12.0.2 brings significant new functionality to all areas of the product, and we believe the new and enhanced functions will help you work more productively. With this release, we continue to provide innovative ways to deliver solutions that meet the next generation of your product design, development, and manufacturing challenges. NX 12.0.2 is robust and powerful, and it delivers advanced technologies for product design, development, and manufacturing in a single, multidisciplinary platform.
This release introduces new assembly load options that can significantly reduce load time on massive datasets. It continues to deliver best-in-class customer deployment readiness, and builds on the productivity and stability achievements of the previous release.
We are confident that NX 12.0.2 transforms the way products come to life, and it will empower you to achieve your next generation of innovation.
About Siemens PLM Software. Siemens PLM Software is a world-leading provider of product lifecycle management and manufacturing operations management software. We help thousands of companies realize innovation by optimizing their processes, from planning and development through manufacturing, production and support.
Product: Siemens PLM
Version: NX 12.0.2 (NX 12.0 MR2) MP03 Update
Supported Architectures: x64
Website Home Page : www.plm.automation.siemens.com
Language: multilanguage
System Requirements: PC
Supported Operating Systems: Microsoft Windows 10 Pro and Enterprise editions
Software Prerequisites: Siemens PLM NX 12.0.2
Size: 997.0 mb
Siemens PLM NX 12.0.2 (NX 12.0 MR2)
Please visit my blog
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please
Please visit my blog
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please