Tags
Language
Tags
December 2024
Su Mo Tu We Th Fr Sa
1 2 3 4 5 6 7
8 9 10 11 12 13 14
15 16 17 18 19 20 21
22 23 24 25 26 27 28
29 30 31 1 2 3 4

Siemens NX 1919 Build 3102 (NX 1899 Series)

Posted By: scutter
Siemens NX 1919 Build 3102 (NX 1899 Series)

Siemens NX 1919 Build 3102 (NX 1899 Series) | 17.0 Gb
Languages: English, 中文, Čeština, Español, Français, Deutsch, Italiano,
日本語, 한국어, Polski, Português, Русский

The Siemens Digital Industries Software development team is pleased to announce the availability of NX 1919 Build 3102 (NX 1899 Series) is a flexible and powerful integrated solution that helps you deliver better products faster and more efficiently. NX series delivers the next generation of design, simulation, and manufacturing solutions that enable companies to realize the value of the digital twin.

1919.3102 Updates - ENHANCEMENTS

Please see below for a list of enhancements included in this release:

- ER9636800 - Sort the planes according to the maximum readability compared to the view normal
- ER9514726 - No longer able to modify specific NX functionality/settings on site level
- ER9653044 - Add palettes to NX18XX out of default NX
- ER9672527 - Administration options for UserPreferences.txt

Line Designer: Connectors and Kinematic components

Sharing connectors and kinematic components in NX managed and native mode

Once you export a plant layout with constraints, attachments, connectors, mounts, and kinematic components to NX native mode, then in NX native you can:

- Import and load the plant layout data and see it in Line Designer for further design.
- View, create, and remove the constraints, attachments, connectors, and mounts of the plant layout, and save. Also use joint jog and pose editor options to create new poses and save.

Now you can import the updated plant layout from NX native to NX managed mode with constraints, attachments, connectors, mounts, and kinematic components using only the Import Manufacturing Assembly into Teamcenter command. This helps you update the plant layout in NX managed mode and share the connection and kinematic components information in Teamcenter.

Siemens NX 1919 Build 3102 (NX 1899 Series)

In NX managed mode, you can now import the Line Designer plant layouts with the updated connections and the kinematic components. Thus, you can share the updated layout information with other users in NX managed mode and across several applications.

Technical documentation

Using connectors and kinematic components in NX native and managed mode

Connectors and connections
In NX native, you can now work with a plant layout containing components that haveassembly constraints, attachments, connectors, and mounts. You can:

- View the connections and connectors and identify which one you want to realign in an assembly.
- Create new assembly constraints and connectors to connect the components.
- Remove the unnecessary connectors, connections, and constraints to stabilize the assembly.

After you update the plant layout in NX native, you can now import the manufacturing assembly with the constraints, attachments, connectors, and mounts into Teamcenter using only the Import Manufacturing Assembly into Teamcentercommand. This helps you share the updated assembly information with other users in NX managed mode and share the connection information across various applications.

Siemens NX 1919 Build 3102 (NX 1899 Series)

Kinematic Components

In NX native, when you work in a plant layout containing the kinematic components, you can:

- Use the kinematic of the components to identify the kinematic resources, and to author kinematics, jog the joints, and create different poses for the kinematic links.
- Define the actual positions of the components, such as robots, stations, tools, and so on. This helps you to identify robot reach and to jog the components to logical positions.

After you update the plant layout in NX native, next you can import the manufacturing assembly with the updates to kinematic components into Teamcenter using only the Import Manufacturing Assembly into Teamcentercommand. This helps you share the kinematics across various applications.

KIA: Support Continuous Release Auto-test Application

Automated Testing Studio

Use the Automated Testing Studio application to record your workflows and to convert them to test cases in NX. When you record test cases, you can create check points by inserting customized validation checks at multiple points. Later, you can run the recorded test cases against a new version of NX to validate your workflows in the NX release that is available for deployment.

Example: You can record a test case for a workflow to create a part, save it, and export it. When you record the test case you can insert a customized validation check to verify if all the part attributes that are required by your organizationwhen you export a part exist in the part. Next, you can run this test case in the current release of NX, check if the validation check passes or fails, and save the result. When the next NX release is available for deployment, you use the test case to compare that release with the release that is currently deployed and create a report that compares the two releases. This helps you verify if your workflow provides the same result in the new version of NXand investigate any discrepancies.

Use these commands to reduce the testing effort that is required to validate your workflows in the new NX release that is available for deployment.

1919,8440155, NX gives intrenal error when saving after deleting operation,CAM,FEATURE_BASED,OTHER
1919,8441054, NX random save unmodified Weld features,ASSEMBLIES,WEIGHT_MANAGE,ALL
1919,8441290, NX unable to publish DB_PART_NO instead of DB_PART_NAME in IBW Connected Parts,KDA,WELD_ASSISTANT,FEATURE_PUBLISH
1919,8442844, Error when using NXOpen.Annotations.DraftingImage.ExportFile(),DRAFTING,ANNOTATION,RASTER_IMAGE
1919,8442883, Error when using NXOpen.Annotations.DraftingImage.GetFileType(),DRAFTING,ANNOTATION,RASTER_IMAGE
1919,8443343, Single Pick in function Identify Results,CAE,ADV_SIMULATION,UNIF_DATA_VIE
1919,8444435, Selecting a Journal folder in Reuse Librari gets error,KDA,REUSE_LIBRARY,LIBRARY_MGT
1919,8445082, EX: Context menu of custom Blockstyler dialog is greyed out by LockAccess(),SYSENG,UI_DESIGN,DYNAMIC_POPUP
1919,8445448, VL2SC: Solver Error for Simulation with Sphere to CAD contact,CAE,MOTION,CONTACT
1919,8568009, Imaginary part of acoustic power is always zero,CAE,ADV_SIMULATION,SYSNOISE_SOLVER
1919,9514726, No longer able to modify specific NX functionality/settings on site level,SYSENG,UI_TOOLS,PALETTES
1919,9626584, Weld preferences - TC Publishing - Part number does not work correctly,KDA,WELD_ASSISTANT,FEATURE_PUBLISH
1919,9636800, Create PMI dim not following default plane perpendicular to current model view,PMI,ANNOT_PLANE,CORE
1919,9653044, Add palettes to NX18XX out of default NX,SYSENG,UI_TOOLS,PALETTES
1919,9663284, NX CAM: Create Tool dialog shows ItemRev IDs instead of process types. GMO DB,CAM,TC_MFG,OTHER
1919,9670865, Executing Journal of CMM function needs cam_base license.,CMM_INSPECTION,ANALYZE,ALL
1919,9672527, Administration options for UserPreferences.txt,SYSENG,UI_TOOLS,PALETTES
1919,9676693, Stock_Preference setting for Stock_Creation_Mode is ignored in 1847 and beyond.,ROUTING_GENERAL,STOCK_AS_COMP,CONVERT_TO_SAC
1919,9682011, "Modeling option ""Delete Child Feature"" does not work for the Weld Assistant bead",KDA,WELD_ASSISTANT,BEAD
1919,9684367, """Pick from Model"" is not displayed in [Nodal Results] of the Identify dialog.",CAE,ADV_SIMULATION,UNIF_DATA_VIE
1919,9686183, Not Run Translator from Pro/e to NX,TRANSLATOR,PROE_INTERFACE,ALL
1919,9691827, Simcenter TBEM - Mapping with absorbent elements,CAE,ADV_SIMULATION,VL2NX_ACOUSTIC
1919,9694516, Solids in top assembly not exported to IFC file,TRANSLATOR,IFC,EXPORT
1919,9695658, Weld Assistant extra spline when workpart is not entire part refset,KDA,WELD_ASSISTANT,OTHER
1919,9697477, Editing a drilling operation causes NX to stop responding,CAM,DRILLING,GEOMETRY
1919,9701521, NX fail to name UGPart when Multifield Key is changed,NXMANAGER,FILE_SAVE_AS,REVISE
1919,9702174, Model and Load Pre-processing solution return Internal Error,CAE,ADV_SIMULATION,NVA_MLD_LD_PP
1919,9702849, NX crashes when using NXOpen.UF.UFDrf.AskImageData(),DRAFTING,ANNOTATION,RASTER_IMAGE
1919,9709059, "Cloning in NX doesn't work with values, which based on dynamic LoVs",NXMANAGER,CLONE,CLONE_ASSEM
1919,9710144, Saving a part with MRL tools fails due to assembly being precise automatically,CAM,TC_MFG,OTHER
1919,9710459, Simcenter 3D - Performance mesh mapping CGNS pressure data,CAE,ADV_SIMULATION,UNIF_DATA_VIE
1919,9715246, NXOpen::UI::LockAccess now also locks all Blockstyler dialog menus and submenus,SYSENG,UI_DESIGN,DYNAMIC_POPUP
1919,9716936, SC3D - Incorrect interpretation of time data in MLPP,CAE,ADV_SIMULATION,VL2NX_ACOUSTIC
1919,9717121, NX fail to name UGPart when Multifiled Key is changed,NXMANAGER,FILE_SAVE_AS,REVISE
1919,9719715, "NXManager gives error ""Working revisions limit exceeded…"" importing part",NXMANAGER,CLONE_IMPORT,IMPORT_ASSEMBLY
1919,9724963, Mold Wizard Collision Clearance value behavior in Run Simulation,KDA,MOLDWIZARD,OTHER
1919,9725169, Outdated JS libraries/files in Environment,ACTIVEWORKSPACE,GRAPHING_COMP,ALL
1919,9726815, EX: Context menu of custom Blockstyler dialog is greyed out by LockAccess(),SYSENG,UI_DESIGN,DYNAMIC_POPUP
1919,9729807, Mechanical Routing: Stock as Component,ROUTING_GENERAL,STOCK_AS_COMP,CONVERT_TO_SAC
1919,9731969, Force and Torque component results are inconsistent between Simcenter 3D UI and,CAE,RESULTS_VIEWER,RESULTS_VIEWER
1919,9747615, SC3D Motion TB not able to run with Tokens,CAE,MOTION,LICENSE_CHECK
1919,9769604, Generating or editing a drilling operation makes NX crash,CAM,DRILLING,GEOMETRY

Siemens NX 1919 Build 3102 (NX 1899 Series)

Siemens NX software is a flexible and powerful integrated solution that helps you deliver better products faster and more efficiently. NX delivers the next generation of design, simulation, and manufacturing solutions that enable companies to realize the value of the digital twin.

Supporting every aspect of product development, from concept design through engineering and manufacturing, NX gives you an integrated toolset that coordinates disciplines, preserves data integrity and design intent, and streamlines the entire process.

Siemens become the first major CAD/CAM/CAE vendor to deliver its software using Continuous Release methodology in January 2019. The new Continuous Release process significantly reduce the time between the proposal of a new enhancement, and its deployment to the end users. Customers will now have the opportunity to deploy the latest NX productivity enhancements more quickly in their production environment which helps them become more productive when using NX. In addition the Continuous Release will also reduce deployment costs for incremental updates.

Adopting a continuous release strategy also allows both Siemens NX and our customers to be more responsive to new ideas and trends in technology, once again allowing our customers to stay ahead of their competition.

NX 1899 - Design Enhanced Patterning


Siemens PLM Software a business unit of the Siemens Digital Factory Division, is a leading global provider of product lifecycle management (PLM) and manufacturing operations management (MOM) software, systems and services with over 15 million licensed seats and more than 140,000 customers worldwide. Headquartered in Plano, Texas, Siemens PLM Software works collaboratively with its customers to provide industry software solutions that help companies everywhere achieve a sustainable competitive advantage by making real the innovations that matter.

Product: Siemens NX
Version: 1919 Build 3102 (NX 1899 Series) *
Supported Architectures: x64
Website Home Page : www.plm.automation.siemens.com
Language: multilanguage
System Requirements: PC **
Supported Operating Systems: **
Size: 17.0 Gb

Siemens.NX.1919.3102.Win64.Full.Setup.iso
Siemens.NX.1919.3102.Win64.Update.Only.iso (NX 1899 pre-install)

Files save in the NX-1899 Series (NX-1899 and higher) cannot be opened in the NX-1872 Series (NX 1872-1892) and lower versions of the NX

Minimum Operating Systems
- Microsoft Windows 10 (64-bit) Pro and Enterprise editions

Windows 10
Windows 10 is the minimum supported release for NX 1899. The supported versions of Windows 10 are the Pro and Enterprise editions utilizing Semi-Annual Channel (SAC) updates.
Windows 7 and 8.1
Windows 7 has reached the end of life and mainstream support has ended. Windows 8.1 is still supported by Microsoft, but was rarely deployed. These two versions of Windows are no longer supported by NX 1899. Siemens PLM Software has not performed testing on these versions and cannot resolve any issues related to NX 1899 running on these operating systems.
Windows XP and Vista
Windows XP support from Microsoft has ended and Vista was rarely deployed so these two versions of Windows are not supported by NX 1899. Siemens PLM Software has not performed testing on these versions and cannot resolve any issues related to NX 1899 running on these operating systems.

Recommended System Configuration:
- 64-bit Windows 10 operating system
- 4 GB RAM minimum, 8 GB or 16 GB RAM recommended
- True Color (32-bit) or 16 million colors (24-bit)
- Screen Resolution: 1280 x 1024 or higher, widescreen format

Please visit my blog

Added by 3% of the overall size of the archive of information for the restoration

No mirrors please


Siemens NX 1919 Build 3102 (NX 1899 Series)