NI LabVIEW 2024 Q3 (x86) with Drivers | 41.8 Gb
NI is now part of Emerson's new Test & Measurement business group has released LabView 2024 Q3. This release brings new features designed to improve collaboration, including configure project save version, improvements to Compare VIs, and a preview of .NET 8.0 support.
LabVIEW 2024 Q4 Features and Changes - Date: July 2024
Preview Feature: .NET Core (8.0) Support in LabVIEW
LabVIEW 2024 Q3 provides limited support for loading and running .NET Core (8.0) assemblies on Windows, including:
- Enabling constructor nodes, property nodes, and invoke nodes to work with .NET Core (8.0)
- Supporting the following four data types:
. int
. string
. bool
. char
To enable .NET Core (8.0) support in LabVIEW 2024 Q3, navigate to Tools » Options, select the Preview Features category, and select the Enable .NET Core (8.0) Support checkbox.
Saving All VIs in a Project for a Previous Version of LabVIEW
You can use the new Save Version option, available in the Properties dialog box of properties, libraries, and classes, to configure LabVIEW to save all VIs for a previous version of LabVIEW. If a VI contains features not compatible with the designated version, LabVIEW displays a warning and saves the VI for the earliest version that supports all features in that VI.
Improvements to Comparing VIs
- You can now highlight an item in the differences list or details list with a single click.
- You can use the left and right arrow keys to move between the differences list and the details list, and you can use the up and down arrow keys to move through the differences and details.
- In the Differences dialog box, a difference or detail appears italicized if it involves only front panel or block diagram cosmetic changes.
- The diagrams can automatically scale to fit an entire difference.
- You can swap the positions of the compared VIs by selecting More commands » Swap VI Positions in the Differences dialog box.
2599334 WebDAV, HTTP, and SMTP Functions Fail to Use Certificates from Files
Configure SSL (WebDAV), Asynchronous Configure SSL (WebDAV), ConfigSSL (HTTP Client), and Config TLS (SMTP) functions fail to use certificate files but do not return errors.
Workaround:There is currently no known workaround for this issue
Offline Help for LabVIEW 2024 Q1 Chinese and Korean Versions Contains Content from LabVIEW 2023 Q3
In LabVIEW 2024 Q1 localized to Chinese or Korean, the offline help included the same contents as the LabVIEW 2023 Q3 help.
Workaround: There is currently no known workaround for this issue.
2645388 Building a Packed Library May Fail Due to Incorrect Path to .NET DLL
In LabVIEW 2024 Q1, building a packed library can fail because LabVIEW incorrectly resolves a relative path to a .NET DLL.
Workaround: There is currently no known workaround for this issue.
2714418 LabVIEW Sometimes Cannot Display File Dialog After Creating Override Methods in a Class
Workaround: There is currently no known workaround for this issue.
2717959 LabVIEW Controls Do Not Receive Mouse Wheel Event with Ctrl Key Pressed
Workaround: There is currently no known workaround for this issue.
742395
LabVIEW Crashes When Comparing VIs with Different Passwords
When comparing VIs that are protected with different passwords, LabVIEW crashes after you enter the passwords.
Workaround: There is currently no known workaround for this issue.
2748388 Compare VIs Does Not Report Difference When Label Changes Attached Object
Workaround: There is currently no known workaround for this issue.
2752615 LabVIEW Editor Responds Slowly with Navigation Window Open and Block Diagram Zoomed
Workaround: There is currently no known workaround for this issue.
2767151 Mass Compile Does Not Update Cache for Some VIs Installed in LVAddons
Mass compile doesn't update the compile cache for VIs installed in the shared LVAddons folder if the VIs are in read-only LLBs. Without an updated cache, TestStand cannot run the VIs using the LabVIEW Run-Time Engine.
Workaround: There is currently no known workaround for this issue.
221246 718006 LabVIEW Does Not Propagate Type Definition Changes to Containers, Causing Unexpected Run-Time Behavior
After you change a type definition's qualified name (for example, by removing it from a class), LabVIEW may fail to apply such change to event refnums or other container data types that include that type definition. VIs that reference the affected container data type won’t show as broken, but may have unexpected run-time behaviorr
Workaround: There is currently no known workaround for this issue.
812117 520215 Find Parallelizable Loops Does Not Analyze VIs Under Targets
Workaround: There is currently no known workaround for this issue.
2597746 LabVIEW Fails to Create Probe for Cluster that Contains IMAQ Image
Workaround: There is currently no known workaround for this issue.
2663212 VI Block Diagram Wires Sometimes Draw Incorrectly on Ubuntu
Workaround: There is currently no known workaround for this issue.
2675593 LabVIEW (64-bit) Sometimes Gives Incorrect Results When Converting Timestamps to Strings with Fractional Seconds Exceeding 19 Digits
Workaround: There is currently no known workaround for this issue.
2682003 Resizing Loops Sometimes Moves Tunnels Unnecessarily
Workaround: There is currently no known workaround for this issue.
2687156 Compare VIs Does Not Report Differences in Window Transparency Values
Workaround: There is currently no known workaround for this issue.
694996 Quick Drop Shortcuts Do Not Work When Placing VIs Shipped with LabVIEW
Workaround: There is currently no known workaround for this issue.
2695155 LabVIEW Can Display the Wrong Portion of a VI Block Diagram During Debugging When Diagram is Zoomed In
Workaround: There is currently no known workaround for this issue.
2707687 In Multi-Monitor Systems, LabVIEW Sometimes Fails to Display the Review and Update from Type Def. Dialog
Workaround: There is currently no known workaround for this issue.
2713392 Compare VIs Does Not Report Adding a Custom Run-time Menu on a Control as a Difference
Workaround: There is currently no known workaround for this issue.
2731705 On Property and Invoke Nodes, the Right-click Help Menu for the Selected Property or Method is Missing
Workaround: There is currently no known workaround for this issue.
Configure SSL (WebDAV), Asynchronous Configure SSL (WebDAV), ConfigSSL (HTTP Client), and Config TLS (SMTP) functions fail to use certificate files but do not return errors.
Workaround:There is currently no known workaround for this issue
Offline Help for LabVIEW 2024 Q1 Chinese and Korean Versions Contains Content from LabVIEW 2023 Q3
In LabVIEW 2024 Q1 localized to Chinese or Korean, the offline help included the same contents as the LabVIEW 2023 Q3 help.
Workaround: There is currently no known workaround for this issue.
2645388 Building a Packed Library May Fail Due to Incorrect Path to .NET DLL
In LabVIEW 2024 Q1, building a packed library can fail because LabVIEW incorrectly resolves a relative path to a .NET DLL.
Workaround: There is currently no known workaround for this issue.
2714418 LabVIEW Sometimes Cannot Display File Dialog After Creating Override Methods in a Class
Workaround: There is currently no known workaround for this issue.
2717959 LabVIEW Controls Do Not Receive Mouse Wheel Event with Ctrl Key Pressed
Workaround: There is currently no known workaround for this issue.
742395
LabVIEW Crashes When Comparing VIs with Different Passwords
When comparing VIs that are protected with different passwords, LabVIEW crashes after you enter the passwords.
Workaround: There is currently no known workaround for this issue.
2748388 Compare VIs Does Not Report Difference When Label Changes Attached Object
Workaround: There is currently no known workaround for this issue.
2752615 LabVIEW Editor Responds Slowly with Navigation Window Open and Block Diagram Zoomed
Workaround: There is currently no known workaround for this issue.
2767151 Mass Compile Does Not Update Cache for Some VIs Installed in LVAddons
Mass compile doesn't update the compile cache for VIs installed in the shared LVAddons folder if the VIs are in read-only LLBs. Without an updated cache, TestStand cannot run the VIs using the LabVIEW Run-Time Engine.
Workaround: There is currently no known workaround for this issue.
221246 718006 LabVIEW Does Not Propagate Type Definition Changes to Containers, Causing Unexpected Run-Time Behavior
After you change a type definition's qualified name (for example, by removing it from a class), LabVIEW may fail to apply such change to event refnums or other container data types that include that type definition. VIs that reference the affected container data type won’t show as broken, but may have unexpected run-time behaviorr
Workaround: There is currently no known workaround for this issue.
812117 520215 Find Parallelizable Loops Does Not Analyze VIs Under Targets
Workaround: There is currently no known workaround for this issue.
2597746 LabVIEW Fails to Create Probe for Cluster that Contains IMAQ Image
Workaround: There is currently no known workaround for this issue.
2663212 VI Block Diagram Wires Sometimes Draw Incorrectly on Ubuntu
Workaround: There is currently no known workaround for this issue.
2675593 LabVIEW (64-bit) Sometimes Gives Incorrect Results When Converting Timestamps to Strings with Fractional Seconds Exceeding 19 Digits
Workaround: There is currently no known workaround for this issue.
2682003 Resizing Loops Sometimes Moves Tunnels Unnecessarily
Workaround: There is currently no known workaround for this issue.
2687156 Compare VIs Does Not Report Differences in Window Transparency Values
Workaround: There is currently no known workaround for this issue.
694996 Quick Drop Shortcuts Do Not Work When Placing VIs Shipped with LabVIEW
Workaround: There is currently no known workaround for this issue.
2695155 LabVIEW Can Display the Wrong Portion of a VI Block Diagram During Debugging When Diagram is Zoomed In
Workaround: There is currently no known workaround for this issue.
2707687 In Multi-Monitor Systems, LabVIEW Sometimes Fails to Display the Review and Update from Type Def. Dialog
Workaround: There is currently no known workaround for this issue.
2713392 Compare VIs Does Not Report Adding a Custom Run-time Menu on a Control as a Difference
Workaround: There is currently no known workaround for this issue.
2731705 On Property and Invoke Nodes, the Right-click Help Menu for the Selected Property or Method is Missing
Workaround: There is currently no known workaround for this issue.
LabVIEW (Laboratory Virtual Instrument Engineering Workbench) is a graphical programming language that uses icons instead of lines of text to create applications. In contrast to text-based programming languages that use instructions to determine the order of program execution, LabVIEW uses dataflow programming. In data flow programming, the flow of data through the nodes on the block diagram determines the execution order of the VIs and functions. VIs, or virtual instruments, are LabVIEW programs that imitate physical instruments. In LabVIEW, you build a user interface by using a set of tools and objects. The user interface is known as the front panel. After you build the front panel, you add code using graphical representations of functions to control the front panel objects. You add this graphical code, also known as G code or block diagram code, to the block diagram. The block diagram somewhat resembles a flowchart. The block diagram, front panel, and graphical representations of code compose a VI.
Introduction to the LabVIEW+ Suite
We’re excited to announce the release of the NI LabVIEW+ Suite. It’s a suite of LabVIEW, plus, more NI software that provides purpose-built tools for automating measurement, analysis, and test. The software works together to save you time.
Emerson is a global technology and software company providing innovative solutions for the world’s essential industries. Through its leading automation portfolio, including its majority stake in AspenTech, Emerson helps hybrid, process and discrete manufacturers optimize operations, protect personnel, reduce emissions and achieve their sustainability goals.
(October 11, 2023) – Emerson has announced it has closed its acquisition of NI (National Instruments), a leading provider of software-connected automated test and measurement systems. The acquisition of NI advances Emerson’s position as a global automation leader and expands its opportunity to capitalize on key secular trends like nearshoring, digital transformation, and sustainability and decarbonization. NI brings a portfolio of software, control and intelligent devices that is expected to accelerate Emerson’s revenue growth aligned to its 4-7% through the cycle organic growth target.
Owner: Emerson
Product Name: NI LabVIEW
Version: 2024 Q3 (24.5.0.49229) with Drivers
Supported Architectures: x86
Website Home Page : www.ni.com
Languages Supported: english
System Requirements: Windows *
Size: 41.8 Gb
Please visit my blog
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please