Tags
Language
Tags
March 2024
Su Mo Tu We Th Fr Sa
25 26 27 28 29 1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30
31 1 2 3 4 5 6

DS SIMULIA CST Studio Suite 2021 SP2 Update

Posted By: scutter
DS SIMULIA CST Studio Suite 2021 SP2 Update

DS SIMULIA CST Studio Suite 2021 SP2 Update | 221.9 mb

Computer Simulation Technology (CST), part of SIMULIA, a Dassault Systèmes brand, announces the release of its flagship EM simulation software, CST Studio Suite 2021 SP2.

General / Environment
- Fixed issue during module start on systems with Chinese Traditional language setting.
- Fixed issue with disabled Ribbon buttons.
- Improved stability when showing key tips.
- Upgraded 3D CAD import to support the latest versions. **New Feature!**
- The cluster integration scripts now support the CHT solver.
- Added Google Chrome for Linux on the list of supported browsers.
- The F7 modified message is now no longer shown, if a project with 0D monitors is saved and opened again.
- Adjusted fast model update behavior, if a "PEC" or "Vacuum" material is renamed.
- During Sub-Project import, the material name, which is used inside of a fluid domain, is now correctly adjusted.
- Improved stability when switching between 3D and Farfield plots .
- Improved display of patch notes in CST Update Manager and CST Studio Suite.
- Fixed wrong help calls in Options dialog box and updated images regarding new Library Paths section.

CST Power'By
- Fixed upload of results when new version is created.
- Fixed creation of Lightweight Visualization with long file paths.
- Allow usage of conversion service for import. **New Feature!**
- Added support for CST Studio Suite Connected. **New Feature!**

System Assembly and Modeling (SAM)
- Do not show misleading warning "Sub-Project import: External reference cannot be found" in simulation projects for block import from the main project.
- Fixed unwanted invalidation of simulation projects using parameterized clone blocks on changing a project parameter used only by the cloned block.
- Field sources are now imported into simulation projects from blocks selected as 3D, which do not contain any other geometry. **New Feature!**
- Do not invalidate simulation project after running it when the project was from an older version.
- Filter Designer 3D assembled optimizations may have multiple S-Parameter producing tasks. **New Feature!**
- Fixed import of more complex assemblies from Antenna Placement App.

EDA Import / EDA Tools
- Fixed issue resulting in invalid bodies for certain complex geometries.

Distributed Computing (DC)
- Fixed parametric setting of distributed optimizer runs when using remote post-processing.

Biological Models
- CST Bio Models Extension 4.0 is now available for download from the Knowledge Base, it also contains the cst file for CST Phone 5G TLM Tutorial. **New Feature!**
- Adjusted values of exemplary thermal properties of several glandular tissues to be more realistic.

Post-Processing
- 5G Post-Processing Wizard: New option to export summary in csv file as well as images of power density plots. **New Feature!**
- ReportTool: restore 1D plot with multi-selected results in schematic.
- Improved handling for large A-solver results.

CST Microwave Studio - General
- Avoid endless loop in case of MPI for SystemCheck that leads to huge log files.
- Handle LSF command line arguments properly in case of spaces for cluster integration scripts.
- New option for HPC cluster simulations to retrieve temporary data and/or additional logging from all compute nodes.
- Adjusted firewall manager to support new MPI locations.
- Specify near field source coupling via tangential fields in online help.
- Enabled S-Parameter sensitivity dB plot.
- Updated online help text for densely sampled near field source data.

CST Microwave Studio - Transient Solver
- Fixed error in field source excitation touching open boundary.
- Fixed port mode plots if there is a slight offset between port coordinates and port grid location.
- Improved result handling for adaptive mesh refinement and line impedance adaptation before solver run.
- Fixed issue with discrete face port detection.

CST Microwave Studio - Transient Solver (TLM Mesh)
- Fixed slots with S-Matrix thin panel material.
- Fixed issue where solver fails when Radiated Power Stop criteria requested without Farfield monitor.
- For newly created models, the default TLM Mesh octree settings (cell lumping) have been modified.

CST Microwave Studio - Frequency Domain Solver
- Added support for conducting-wall boundary condition to the Spark3D export tool.
- In rare cases with close low frequency samples, the frequency sweep did not provide broadband results.

CST Microwave Studio - Frequency Domain Solver (Tetrahedral Mesh)
- Increased the results accuracy using non-rectangular numerical discrete face ports and lumped elements.
- Fixed rare performance degradation for the direct solver in setup phase.
- A protected frequency domain solver project can now import field sources from not protected projects.

CST Microwave Studio - Integral Equation Solver
- Enabled the use of preconditioner type 4 with thin-panel defined by S-matrix table.
- Generate error message for unsupported thin-panel type using reflection and transmission table.

CST Microwave Studio - Asymptotic Solver
- Fixed Farfield calculation for thick dielectrics when hardware acceleration is active.
- Added functionality to switch value for plotting trapped rays in dialog. **New Feature!**

CST Cable Studio
- Fixed issue with dragging of wires when creating a cable group.
- Show RLCG-values for discrete frequencies also for sets.
- Fixed tcf file read error that can occur in case current probes are defined.
- Repaired inconsistency with identifiers when creating materials.

CST EM Studio - LF Frequency Domain Solver (Tetrahedral Mesh)
- Corrected simulation of dispersive materials in broadband computations.
- Ensured that mixed setups composed of solid and eddy-current free CAD coils can be simulated.
- Ensured that mixed setups composed of current ports and solid CAD coil segments can be simulated.
- RMS source scaling is now handled correctly.
- React quicker on a user abort during the stationary current precomputations.

Fest3D
- Resolved behavior in coaxial cavity elements, which could not use parameters in rounding specifications of the element.
- Corrected the behavior where circuits from versions 2018 & 2019 lost their parameters if being imported directly in the 2021 version.
- Resolved loss of accuracy in results of a complex example with respect to Fest3D 2020.
- Resolved behavior when user uses copy/paste after changing to a different circuit.
- Removed warning message provided to the user once a tolerance analysis was finished.
- Fixed issue when updating results in CST Studio Suite using a project exported to DES by Fest3D.
- Fixed shape plot for Arbitrary Shaped Elements when parameters were used in the element to be plot.

CST PCB Studio
- Package with missing electrical connection can cause problems later on. Warn the user when manually creating such contradictions.
- Pick the correct differential partner pin in old projects and handle more cases in exiting checks.
- Fixed issue with updating of SP layout when running convenient workflow.
- Have additional net name in Eye and Timing result items.
- Fixed gap healing to have a 2DTL connection.
- Fixed issue with dialog boxes initialization on Linux.

CST Design Studio - General
- Schematic Editor text fields: The font name and font size comboboxes in the Ribbon now work as expected.
- Added hexagonal shapes for mask violation analysis in eye analysis task. **New Feature!**
- The block parameter 'Solver' and its children are now invalidated on other block parameter changes.
- The channel parameter of an IBIS AMI task is not always red anymore.
- Fixed wrong simulation results for some Coilcraft devices by considering ZO as alias to Z0 for ideal transmission lines.
- Fixed the pin layout of Microstrip/Stripline coupled lines.
- Fixed displaying wrong model type after switching a centered microstrip t junction block from 2D EM model to standard model.
- Enabled creation of stand-alone eye analysis task via source task selection. **New Feature!**
- Ensured that drag&drop is disabled in the View Pin Layout dialog box.
- Repaired add image workflow.
- Implemented IdEM service abort button.
- Fixed issues with unit display in the block parameter list.
- Automatically create mirrored groups when element symmetry is defined.

CST Design Studio - Hybrid Solver Task
- Fixed result invalidation on changing Hybrid Solver Task parameters.
- Do not overwrite observation sweep angles in local A-solver domains by Hybrid Solver Task.
- Automatically run with at least 2 samples if fmax > fmin.
- Prevent history error messages during start of Hybrid Solver Task in certain circumstances.
- Added description of NFD file format.
- Fixed missing simultaneous excitations with '[…]' characters.
- Update Hybrid Solver Task UI on changes in local domains.

CST Design Studio - Machine Simulation Sequence
- Support rotor skewing for ROM Drive Scenario (also available in EMAG-ROM for Simpack). **New Feature!**
- Functional Mock-up Unit (FMU) of nonlinear ROM supports extrapolation to handle exceeding machine currents. **New Feature!**
- Operating Point Look-up FMU features new look-up modes, such as limiting to max motor curve or max generator curve. Moreover, support negative revolution speed and cover exceeding speed limits by extrapolation. **New Feature!**
- FMUs in general can handle non-trivial resource locations (space, non-ASCII).
- Various fixes for the user interface.

System Simulator
- "About" icon in SytemSimulator now redirects to 3DS webpage.
- Removed MotorCad-Import icon and a corresponding menu item since this functionality is not included into the SystemSimulator.
- Curve and axis colors can now be changed via Outputs Properties dialog box.

IdEM
- Fixed error in setting up some IdEMXpress options, options are now preserved.
- Fixed error in setting up plot properties of responses plotted in Real/Imag form.
- Fixed error in fitting options XML file, custom "bandwidth" parameter is now correctly written.
- Fixed discrepancy in the maximum error value when it is visualized in the log and in the figure container.

Automation / Macros / Result Templates / External Data Access
- Fixed default logfactor=20 for complex 1D VBA objects.
- Fixed Plot1D.AddMarker and Plot1D.AddMarkerToCurve VBA functions.
- Improved DES macro "Construct/Add Ports to all pins of a block" (enable connecting bus pins and use string names instead of deprecated numbers).
- Using CreateMailslot and GetMailslotInfo will work correctly for Windows again.
- Added missing Python extension modules for Python 3.7 and 3.8.

DS SIMULIA CST Studio Suite 2021 SP2 Update

CST STUDIO SUITE is a package of tools for designing, simulating and optimizing electromagnetic systems, and is used in leading technology and engineering companies around the world- The three pillars of CST products are accuracy, speed and usability.

Communication system design is getting challenging today since antenna, microwave component and electronics performances have to be proven when they are installed in their working environment.

SIMULIA CST Studio Suite 2021 introduces a range of new enhancements and improvements to increase the versatility and performance in modeling, meshing and solver technologies exactly to solve these issues.

In addition, the integration on the 3DEXPERIENCE platform enables seamless collaboration workflows, even among different teams and departments. Users will be able to make necessary changes to the product quickly, improving engineering efficiency and further boosting innovation.

CST Studio Suite Electromagnetic - Structural Simulation Smartwatch Demo


CST is a market leader in providing 3D electromagnetic (EM) field simulation tools through a global network of sales and support staff and representatives- CST develops CST STUDIO SUITE, a package of high-performance soft-ware for the simulation of EM fields in all frequency bands- Its growing success is based on a combination of leading edge technology, a user-friendly interface and knowledge-able support staff- CST solutions are used by market leaders in a diverse range of industries, including aerospace, auto-motive, defense, electronics, healthcare and telecommuni-cations- CST is part of SIMULIA, a Dassault Systèmes brand-

Product: CST Studio Suite
Version: 2021 SP2 Update
Supported Architectures: x64
Website Home Page : www-3ds-com
Language: english
System Requirements: PC *
Software Prerequisites: CST Studio Suite 2021 and above
Size: 221.9 mb

CST Studio Suite Recommended Hardware

EM simulations can be classified as high performance computing tasks. This means that computers used for CST applications must meet high requirements in terms of CPU, RAM, and graphical specifications in order to achieve optimal performance. Sufficient power supply and cooling must also be ensured for the workstation or server. We strongly recommend buying a complete package from a brand-name manufacturer, e.g. DELL, HP, or IBM, and that the chosen hardware meets the following requirement

Processor
Minimum requirement: Intel x86-64 processor
High end server/workstation recommendation: Dual 2nd Generation Intel Xeon Scalable Processors (also known as „Cascade Lake“)
Notes for recommended hardware: We recommend high processor base clock frequency (>3 GHz) and 8-10 cores per CPU are recommended for general-purpose simulation workstation
Memory (RAM)
Minimum requirement: 16 GB
High end server/workstation recommendation: 32–64 GB per CPU
Notes for recommended hardware: We recommend fastest RAM memory modules available, currently DDR4-2933.
Graphics card
Minimum requirement: 100% OpenGL compatible graphics card
High end server/workstation recommendation: NVIDIA Quadro series card dedicated to CAD/CAE applications
Notes for recommended hardware:
Storage
Minimum requirement: 30 GB of free disk space
High end server/workstation recommendation: At least 500 GB hard disk drive
Notes for recommended hardware: SSDs may be used, but are not necessary for good simulation performance
GPU computing (optional)
Minimum requirement: Supported GPU card
High end server/workstation recommendation: High-end NVIDIA Quadro or Tesla card
Notes for recommended hardware: Please refer to the GPU computing guide
MPI computing (optional)
Minimum requirement: Dedicated compute cluster hardware
High end server/workstation recommendation:
Notes for recommended hardware: Fast network interconnects with low latency, e.g. Infiniband or Intel OmniPath, are strongly recommended. Please refer to the MPI computing guide
Distributed computing (optional)
For optimal simulation performance, the solver servers should run on separate computers from the frontend and the main controller. A fast network connection between the solvers servers, the main controller, and the frontend is recommended as simulations may generate a lot of data that needs to be transferred.

CST Studio Suite - Operating System Support

Windows 7 / Server 2008 R2 SP1
Windows 8.1 / Server 2012 R2 *
Windows 10
Windows Server 2016 **
Windows Server 2019 **

* Support can’t be guaranteed. (only for FEST3D)
** Operating system is not yet or no longer supported. Our software is not tested on this platform. (only for SPARK3D and FEST3D)

DS SIMULIA CST Studio Suite 2021 SP1

Please visit my blog

Added by 3% of the overall size of the archive of information for the restoration

No mirrors please


DS SIMULIA CST Studio Suite 2021 SP2 Update